Appendix A: EM Observe Event Reference

Created by Matthew St. Louis, Modified on Tue, 21 Apr at 4:38 PM by Matthew St. Louis

APPENDIX A

EVENT REFERENCE

Event records are indicated as icons along the top of the time series and may include events related to system performance, system activity, or user interactions. The following events are for the EM Observe System.


CodeEvent TypeDescription
1Startup NormalStart-up from a controlled shutdown. This includes the power switch being pressed, shutdown by technician, and battery dead.
2Startup From Watchdog Data MediaLogged when EMR could not get access to data media and rebooted the system.
3Startup From Power Fail or Watchdog During Automatic RecordingLogged if automatic recording was occurring at the time of shutdown. Power failure: control centre completely loses power. Watchdog: software locks up (a pulse is not received every 10 seconds within 1 minute duration).
4Startup From Power Fail or WatchdogWhen a new data collection period is started, all events are cleared so there is no shutdown event from the previous shutdown. As a result, this will always be the first start-up event.
5Startup From WD ADROnly available in EM Observe v4.2. Preceded by ‘Shutdown Resetting ADR’ event.
6Startup From WD GPSOnly available in EM Observe v4.2. Preceded by ‘Shutdown Resetting GPS’ event.
7Preceded by ‘Shutdown Enter Sleep Mode’ event.
8–9Unassigned
10Shutdown TechnicianRefers to closing down of data logger software, not the control centre. Indicated when a technician logs out of the user account or shuts down the software in the tech account. Will be followed by a ‘Startup Normal’ event.
11Shutdown Enter Sleep ModeIn EM Observe v4.2, sleep mode is available through the SPS in DC systems only. In EMO v4.5, sleep mode relies on the sleep sensor rather than AC or DC power. Will be followed by a ‘Startup from Sleep’ event.
12Shutdown Battery DeadOnly available with EMO v4.2. Indicated if battery dead, shutting down before power gets turned off by SPS. Will be followed by a ‘Startup Normal’ event.
13Shutdown Resetting ADROnly available with EMO v4.2. Communication error with the ADR that cannot be fixed unless the system is shutdown. Will be followed by a ‘Startup from Watchdog ADR’ event.
14Shutdown Resetting GPSOnly available with EMO v4.2. Communication error with the GPS that cannot be fixed unless the system is shutdown. Will be followed by a ‘Startup from Watchdog GPS’ event.
15Shutdown Program LockupWhen an EMR shutdown is already in progress but some components are non-responsive and possibly crashed or locked up.
16Shutdown Test Sleep
17Shutdown WatchdogWhen the EMR software fails to contact the system watchdog, which after 2 minutes preemptively restarts the system control center, presuming that the software is crashed or locked up.
18Shutdown by UDP
19Shutdown DIR Close PeriodWhen the vessel DIR is run and EMO is shutdown from there.
20GPS Checksum ErrorWhen a GPS sentence is received with an error checking number that does not match the calculated one, indicating an error in the data.
21GPS Data BadThe calculated GPS data is outside its acceptable margin of error, indicating insufficient GPS signal for an accurate position.
22GPS Data GoodThe calculated GPS data is again within its acceptable margin of error. Positioning is accurate.
23GPS DataStream OffOccurs when a GPS is receiving power but the data wire is not transmitting data, resulting in a loss of streaming GPS data.
24GPS DataStream OnOccurs when the GPS data wire begins transmitting data again. Streaming GPS data resumed.
25Comm1 Not Available
26Comm2 Not Available
27ADR2100 Not RespondingOccurs when EMR is not able to communicate with the ADR2100. This is a rare event, as it tries approximately 100 times to communicate before logging.
29End of Functionality TestLogged when a function test has been completed.
30Function Test by Technician‘Run a system function test’ while in the technician account.
31Function Test by Vessel‘Run a system function test’ while in the user account.
32Function Test AbandonedLogged when a function test was not completed.
33Start SetIndicated when Start Set is highlighted in the ‘Enter an Event Marker’ button on the Main Controls tab.
34End SetIndicated when End Set is highlighted in the ‘Enter an Event Marker’ button on the Main Controls tab.
35Start HaulIndicated when Start Haul is highlighted in the ‘Enter an Event Marker’ button on the Main Controls tab.
36End HaulIndicated when End Haul is highlighted in the ‘Enter an Event Marker’ button on the Main Controls tab.
37New Comment EventIndicated when information is entered in the ‘Enter a Comment’ button on the Main Controls tab.
38Edit Comment Event
40Start Automatic RecordingCameras are triggered according to the software mode specified.
41Stop Automatic RecordingCameras are closed according to the software mode specified.
42Stop Automatic Recording Technician
43Start Manual RecordingCameras are triggered when ‘Turn Video Recording On’ is selected on the Main Controls tab.
44Stop Manual RecordingCameras are closed when ‘Turn Video Recording Off’ is selected on the Main Controls tab.
45SPS - Sensing Charging BatteryOnly available with EMO v4.2. The SPS reads that the vessel’s battery supply is charging.
46SPS - Sensing Normal BatteryOnly available with EMO v4.2. The SPS reads that the vessel’s battery voltage is sufficient to run the EM system.
47SPS - Sensing Low BatteryOnly available with EMO v4.2. The SPS reads that the vessel’s battery voltage is insufficient to run the EM system.
48Reset SensorsOnly available with EMO v4.5. If the GPS or sensors lock up, power to the sensors (not the control centre) is turned off for 5 seconds.
49Update System ClockOccurs on every startup to ensure the dataset has the correct time. If the EMO clock drifts greater than +/– 1 second, the system clock is updated.
50Unlock SystemTechnician selects the ‘Unlock System’ button and enters the password to unlock a tab in the user account.
51Lock SystemTechnician selects the ‘Lock System’ button to lock a tab in the user account.
52Inside Port AreaVessel is within a Port Box boundary as defined in the Port Areas.
53Outside Port AreasVessel is outside a Port Box boundary as defined in the Port Areas.
54Enter Fishing AreaCurrently not in use.
55Leave Fishing AreaCurrently not in use.
56Enter Restricted AreaCurrently not in use.
57Leave Restricted AreaCurrently not in use.
58Vessel Power OffOnly available with EMO v4.5. Indicated when the power entering the EMO unit is disrupted.
59Vessel Power OnOnly available with EMO v4.5. Indicated when the power entering the EMO unit is restored.
60UPS Capacity < 40%Only available with EMO v4.5. There is less than 40% life remaining for the UPS battery.
61UPS Capacity > 50%Only available with EMO v4.5. There is more than 50% life remaining for the UPS battery.
62UPS Temperature < 50°COnly available with EMO v4.5. Logged after temperature has gone above 50°C and then come down again.
63UPS Temperature > 50°COnly available with EMO v4.5. Temperature is reaching the upper operating limit. EMO will shutdown if temperature exceeds 55°C for 20 continuous seconds.
64Disk Getting FullLogged when available disk space drops under 10 GB. EMR displays a ticker-tape message: “Data disk is getting full.”
65Disk Is FullLogged when available disk space drops under 2 GB. EMR displays: “Data disk is full – CHANGE DISK NOW” and stops video recordings.
70Shutdown UPS Battery LowOnly available with EMO v4.5. If the UPS battery drops to 30% capacity, the system will start a controlled shutdown. Will be followed by a ‘Startup Normal’ event.
71Shutdown Power Switch PressedOnly available with EMO v4.5. The power switch on the front of the control centre was pressed. Will be followed by a ‘Startup Normal’ event.
72Shutdown UPS Over TemperatureOnly available with EMO v4.5. Logged when temperature exceeds 55°C for 20 continuous seconds.
73Shutdown Resetting Data MediaEMR checks the data disk periodically. If EMR can’t connect to the data disk for 10 seconds, it restarts EMO in hopes of recovering operations.
74Shutdown Default No Specified ReasonLogged when the VDL is being shut down and the reason for the shutdown is not any of the enumerated possible reasons. Each enumerated reason has its own specific event code that will override this default code.
75Shutdown Invalid SystemLogged when the VDL is being shut down because of “InvalidSystem,” which happens for reasons such as: trip not closed properly, non-blank hard drive, technician required to initialize system, no hard drive, or AMRGINA not running.
76Shutdown Redo Hung Camera InitializationLogged when the VDL is being shut down because one or more cameras failed to finish initializing.